Stellium 1

Stellium Datacentres Limited · Newcastle upon Tyne · Regional UK · United Kingdom

Design resilience tier
III
Redundancy (as published)
There are dual 40 MVA feeds coming from the 275kV national grid delivering N+N capability to data centre 1 - Sector 1. Each sector (data hall) operates off its own independent power and cooling infrastructure. There is N+N redundancy of Uninterruptable Power Supplies (UPS). UPS is a 2N redundant system as per IEEE Std. 3006.7-2013. N+1 redundant generators for the entire site power including the IT load & mechanical load. N+N power is provided to customer racks. The PDUs/RPPs are of 2N (A&B) configuration with diverse routes and location. Our cooling has redundancy of N+1 on the central chillers and N+4 on the down-flow cooling units. System is 100% concurrently maintainable at every bus with dual corded IT load. Our colocation data centres meets all Tier 3+ requirements of concurrent maintainability, diverse engineering and avoidance of single points of failure. We have on-site diesel storage which is sufficient for 48 continuous operation on full load.
Floor area
4,264 m² whitespace
Security
24/7 on-site security
Year built
2016
Rack density
4–50 kW · up to 100 kW liquid-cooled

Platform reviewed · 05 Sept 2026 · Recent

Density (as published)
Rack cooling from 4 kw to 50 kw (scalable to 100 kw) (FAQs); 11MW IT power delivering 8kW racks (3kW per square metre) across each data hall, with a local capability of up to 50kW per rack; HPC cooling of client racks from 10 to 100kW using in-row/rear door chilled water cooling; Bespoke designs available for fully immersive cooling up to 200kW per rack can be supported; N+ N 230/400V power feeds to racks via tap off units in 16A, 32A, 63A in single or 3 phase configuration
Power band
5–20 MW

Platform reviewed · 05 Sept 2026 · Recent

Cooling
Air cooling, Free cooling, Rear-door heat exchanger, Immersion
Availability
Available

Platform reviewed · 05 Sept 2026 · Recent

Cross-connect
On request
Renewable power
100% renewable power
Design PUE
Design PUE 1.2 to 1.4
PUE note
Verified design PUE of 1.24 within recommended temperature and humidity ranges; another operator page gives 1.2.
Services
Colocation, connectivity and high-density
Certifications 11
ISO 27001Cyber EssentialsISO 9001ISO 14001ISO 22301ISO 20000-1BREEAMEU Code of ConductCyber Essentials+PSN NetworkBREEAM Outstanding

Location

View on the full map · Elevation At sea level

Aerial view of Stellium 1
Aerial view of the site. Imagery MapTiler, OpenStreetMap contributors.

Interested in this location? Send one inquiry with your requirements and receive a response within one business day.

Data sources

This profile is based on public sources; the operator has not yet confirmed its data. Confirmed data carries the Verified badge and a confirmation date.