R-KOM Datacenter Ostbayern 1

R-KOM GmbH · Regensburg · Regional Germany · Germany

Design resilience tier
III
Redundancy (as published)
Multiply redundant internet connections and uninterruptible power supply (UPS) secure your data access and power needs. Power is supplied via a redundant connection to the medium-voltage grid of REWAG and offers a secure power supply. Separate UPS systems (uninterruptible power supply) are available for secure operation. A redundantly built power supply guarantees a secure supply of the data centres. The customer racks are located in two IT rooms separated for fire protection. These are equipped with redundant power connections (PDUs) and offer a UPS-protected power supply. The distribution of our data centres over 3 sites also guarantees the highest resilience and redundancy. Service description Datacenter Ostbayern (Dlbs041-08, valid from 01.08.2023): the R-KOM data centres offer in redundant configuration: air-conditioned rooms, uninterruptible power supply with standby power plant, very early fire detection and fire extinguishing system and connection to the public internet. The R-KOM data centres are equipped with redundant air conditioning, redundant UPS systems, standby power plant, where applicable raised floor, fire alarm system, where applicable fire extinguishing system and video surveillance. The data centres are equipped with two separate, redundant medium-voltage connections. The power feeds are secured by separate UPS systems and a shared standby power plant (diesel generator set) for RZ 1 and RZ2. Brochure "Die Rechenzentren der R-KOM" (Dmar160-01a, 2023): redundant medium-voltage supply and transformers as well as UPS for protection against power failures.
Rack density
3 kW

Platform reviewed · 04 Sept 2026 · Recent

Density (as published)
Maximum capacity 19" rack: 3.000 watts (RZ1); 19" partial rack 10 U: 1.000 watts (RZ1); minimum capacity/minimum purchase 19" rack 1.000 watts, partial rack 500 watts, rack space 1 U 300 watts. Connection RZ1: rack space 1 U 1 x 16 ampere socket (RZ1); partial rack 2x16 ampere power strip each on 2 separate UPS systems (UPS A / B) (RZ1 & RZ2); rack one 16 ampere power strip per phase on 2 separate UPS systems (UPS A / B) (RZ1 & RZ2). Rack units 19" rack: min. 40 (=1.800 mm) (RZ1); rack depth 1000 mm (RZ1). (service description Datacenter Ostbayern, Dlbs041-08, valid from 01.08.2023, annex 1); "Uninterruptible power supply with up to 8 kW power draw" for package M and "up to 2 kW" for package S on the website.
Cooling
Air cooling, Free cooling
Availability
Availability on request

Imported · Recorded 08 Jun 2026 · Not recent

Cross-connect
On request
Renewable power
100% renewable power
Services
Colocation and connectivity
Certifications 2
ISO 27001TÜV Trust IT

Location

View on the full map · Elevation 337 m above sea level

Aerial view of R-KOM Datacenter Ostbayern 1
Aerial view of the site. Imagery MapTiler, OpenStreetMap contributors.

Interested in this location? Send one inquiry with your requirements and receive a response within one business day.